Slot: Uncertainty (uncertainty)

It is recommended to provide uncertainty for each data point in the data file. Else provide a single value representative of the dataset.

If uncertainty is provided as a variable, please list the column header name here.

URI: oae:uncertainty

Applicable Classes

Name Description Modifies Slot
MeasuredVariable Variable that is directly measured in-situ using instruments yes
DiscreteTAVariable Total Alkalinity (TA) measured variable from discrete bottle samples no
ContinuousDICVariable Dissolved Inorganic Carbon (DIC) measured variable from continuous autonomous... no
ContinuousTAVariable Total Alkalinity (TA) measured variable from continuous autonomous sensor no
QCFields Quality control fields applicable to measured and calculated variables no
ContinuousCO2GasDetector CO2 gas detector for continuous measurements, with measurement frequency no
CO2GasDetector CO2 gas detector with standard gas calibration no
ContinuousCO2Variable CO2 continuous (sensor) measured variable (xCO2/pCO2/fCO2) no
DiscreteSedimentVariable Measured sediment variable collected from discrete bottle samples no
ContinuousPHVariable pH measured variable from continuous autonomous sensor no
DiscreteDICVariable Dissolved Inorganic Carbon (DIC) measured variable from discrete bottle sampl... no
StandardGas Standard gas used for CO2 calibration no
ContinuousMeasuredVariable A variable measured in-situ by a continuous autonomous sensor (e no
DiscreteMeasuredVariable A variable measured in-situ from discrete water samples (e no
DiscreteCO2Variable CO2 discrete (bottle) measured variable (pCO2/fCO2) no
HPLCVariable HPLC (High-Performance Liquid Chromatography) measured variable for pigment a... no
CalculatedVariable A variable that is calculated or derived from other measured variables rather... no
DiscretePHVariable pH measured variable with dye-based spectrophotometric measurement no
ContinuousSedimentVariable Measured sediment variable collected from continuous autonomous sensor no
ContinuousStandardGas Standard gas used for continuous CO2 calibration, with additional traceabilit... no

Properties

Identifier and Mapping Information

Schema Source

  • from schema: https://schema.oaedata.org/OAEDataSchema

Mappings

Mapping Type Mapped Value
self oae:uncertainty
native oae:uncertainty

LinkML Source

name: uncertainty
description: 'It is recommended to provide uncertainty for each data point in the
  data file. Else provide a single value representative of the dataset.

  If uncertainty is provided as a variable, please list the column header name here.'
title: Uncertainty
from_schema: https://schema.oaedata.org/OAEDataSchema
rank: 1000
alias: uncertainty
domain_of:
- StandardGas
- CO2GasDetector
- QCFields
range: string